Octave-Wcalc: ic_microstrip_calc

ic_microstrip_calc - Integrated circuit microstrip transmission line analysis

SYNOPSIS

[z0, keff, elen, loss, L, R, C, G] = ic_microstrip_calc(w, l, tox, h, er, sigmas, tmet, rho, rough, f)

PARAMETERS

INPUT PARAMETERS

  • w : width of ic_microstrip line (meters)
  • l : lentgh of ic_microstrip line (meters)
  • tox : oxide thickness (meters)
  • h : substrate thickness (meters)
  • er : substrate relative permitivity
  • sigmas : substrate conductivity (1/ohm-m)
  • tmet : metal thickness (meters)
  • rho : resistivity of wire (relative to copper)
  • rough : conductor surface roughness (meters-rms)
  • f : synthesis frequency (Hz)

OUTPUT VALUES

  • z0 : calculated characteristic impedance (Ohms)
  • keff : calculated effective relative permitivitty
  • elen : calculated electrical length of the line (degrees)
  • loss : calculated loss of the line (dB)
  • L : calculated inductance per length (Henries/meter)
  • R : calculated resistance per length (Ohms/meter)
  • C : calculated capacitance per length (Farads/meter)
  • G : calculated conductance per length (Siemens/meter)

DESCRIPTION

Function to analyze the electrical characteristics of a single integrated circuit microstrip transmission line. The physical dimensions of the microstrip line are given as inputs and the characteristic impedance, effective dielectric constant, loss and open circuit end correction are calculated.


                 |<--W-->|
                  _______    
                 | metal | <- tmet,rho,rough
    ----------------------------------------------
   {**************  Oxide (tox,eox) **************
    ----------------------------------------------
   (  substrate                          /|\     (
    )   es,sigmas                     H   |       )
   (                                     \|/     (
    ----------------------------------------------
    XXXXXXXXXXXXXXXXXX ground XXXXXXXXXXXXXXXXXXXX

EXAMPLE

 % width
w=150e-6;
 % substrate height
h=250e-6;
 % length
l=1000e-6;
 % substrate permitivitty
es=11.8;
 % substrate conductivity
sigmas=0.5;
 % oxide thickness
tox=1.5e-6;
 % oxide permitivitty
eox=4;
 % metal thickenss
tmet=0.8e-6;
 % metal resitivity
rho=3.0e-8;
 % metal surface roughness
rough=0.0;
 % frequency
f=2.4e9;
[z0,keff,elen,loss,L,R,C,G] = ...
  ic_microstrip_calc(w,l,tox,eox,h,es,sigmas,tmet,rho,rough,f);
disp(sprintf('z0 = %8.4g + j %8.4g Ohms', real(z0), imag(z0) ));
disp(sprintf('keff = %8.4g ',keff));
disp(sprintf('elen = %8.4g degrees',elen));
disp(sprintf('loss = %8.4g dB',loss));
disp(sprintf('L  = %8.4g nH/mm', L*1e6));
disp(sprintf('R  = %8.4g Ohm/mm', R*1e-3));
disp(sprintf('C  = %8.4g fF/mm', C*1e12));
disp(sprintf('G  = %8.4g uMho/mm', G*1e3));

SEE ALSO

air_coil_calc
air_coil_syn
coax_calc
coax_syn
coplanar_calc
coplanar_syn
coupled_microstrip_calc
coupled_microstrip_syn
coupled_stripline_calc
coupled_stripline_syn
ic_microstrip_calc
ic_microstrip_syn
microstrip_calc
microstrip_syn
stripline_calc
stripline_syn

AUTHOR

Dan McMahill

BUGS

None known

Please report any bugs on the Wcalc Sourceforge Project Page

Return to the Octave-Wcalc page.

Wcalc Logo

Information
 About Wcalc
 Reporting bugs
 Current projects
 Obtaining Wcalc
 Technical Notes
 Wcalc F.A.Q.
 Wcalc Home
 Wcalc Sourceforge Project

Models
 Air Core Solenoid Inductor
 Parallel Rectangular Bars Inductance
 Coaxial Transmission Line
 Coplanar Waveguide
 Coupled Microstrip
 Coupled Stripline
 Integrated Circuit Microstrip
 Microstrip
 Series/Parallel RC Network
 Series/Parallel RL Network
 Stripline

Frontends
 CGI-Wcalc (Web Interface)
 GTK-Wcalc (GUI Interface)
 MEX-Wcalc (Matlab Interface)
 Octave-Wcalc (Octave Interface)
 SCI-Wcalc (Scilab Interface)
 STDIO-Wcalc (Simple stdio Interface)

Misc. Info.
 Permeabilities
 Permitivities
 Resistivities
 Unit Conversion Factors
 Wire Sizes

   
Copyright © 2001, 2002, 2004, 2005, 2006 Dan McMahill ALL RIGHTS RESERVED.